Home›Repair guides›Kohler›Ignition Timing (Magneto)

Kohler L600 / L654 — Ignition Timing (Magneto)

Adjustments

For the Kohler L600 / L654, from the Kohler service manual.

Browse Kohler generators & specs →

Before you start

  • Do not connect a battery to the magneto as this will ruin the coil windings.

Procedure

  1. After making sure breaker point gap is properly set, connect timing light to #1 cylinder then start engine.
  2. Aim timing light into pointer area on bell housing - SPK mark should be even with the pointer just as the light flashes.
  3. If not, loosen (do not remove) the two magneto mounting capscrews and shift magneto (top flange eccentric) until SPK mark is exactly centered.
  4. Retighten mounting capscrews after proper timing is attained.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.