Kohler L600 / L654 — Generator Removal
Repair & overhaul
For the Kohler L600 / L654, from the Kohler service manual.
Browse Kohler generators & specs →
Procedure
- Before detaching generator, place blocks of wood under the oil pan on marine models or under the generator frame on other models.
- Disconnect leads from engine to controller.
- Remove generator end cover then lift AC and DC brushes off slip rings and commutator.
- Remove bracket armature thru bolt then install standard puller and remove generator frame and end as a unit.
- To remove armature from tapered portion of crankshaft, reinstall thru bolt about halfway, hold armature to prevent falling and tap end of bolt sharply with a steel hammer.
Tools required
- standard puller
- steel hammer Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.