Home›Repair guides›Kohler›Generator Removal

Kohler L600 / L654 — Generator Removal

Repair & overhaul

For the Kohler L600 / L654, from the Kohler service manual.

Browse Kohler generators & specs →

Procedure

  1. Before detaching generator, place blocks of wood under the oil pan on marine models or under the generator frame on other models.
  2. Disconnect leads from engine to controller.
  3. Remove generator end cover then lift AC and DC brushes off slip rings and commutator.
  4. Remove bracket armature thru bolt then install standard puller and remove generator frame and end as a unit.
  5. To remove armature from tapered portion of crankshaft, reinstall thru bolt about halfway, hold armature to prevent falling and tap end of bolt sharply with a steel hammer.

Tools required

  • standard puller
  • steel hammer Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.