Home›Repair guides›Kohler›Distributor Retiming

Kohler L600 / L654 — Distributor Retiming

Adjustments

For the Kohler L600 / L654, from the Kohler service manual.

Browse Kohler generators & specs →

Procedure

  1. Establish firing position of #1 cylinder: rotate engine by hand until SPK timing mark lines up and compression is felt in #1 cylinder.
  2. With distributor removed from engine, remove distributor cap, rotor and cover.
  3. Reinstall rotor and rotate drive gear until ignition points just begin to open when rotor is positioned to fire #1 spark plug.
  4. Install distributor on engine.
  5. Reassemble cover, rotor and cap in proper position; connect spark plug leads as indicated.
  6. Use a timing light for precision timing of the ignition.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Distributor breaker point gap .020 in

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.