Home›Repair guides›Kohler›Water pump LT removal and installation

Kohler KD62V12 — Water pump LT removal and installation

Repair & overhaul

For the Kohler KD62V12, from the Kohler service manual.

Applies to: Kohler KD62V12, Kohler KD62V12 engine

Before you start

  • Replace all sealings
  • Vent coolant circuit at the end of installation

Procedure

  1. Drain LT coolant circuit; remove machinery LT cooling system piping, vibration damper cover and battery charging alternator cover.
  2. Remove screws and piping assemblies.
  3. Remove screws; remove water pump LT.
  4. Installation: install guiding rods; insert O-rings; insert water pump LT.
  5. Place four screws; remove guiding rods; place remaining screws.
  6. Assemble elbow pipe with flange and O-rings; tighten screws.
  7. Assemble branch pipe with pipe and flange with O-rings; position and tighten.
  8. Vent coolant circuit at the end.

Tools required

  • Guiding rod M12x100 - Water pump (x2) Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Kohler KD62V12 →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.