Home›Repair guides›Kohler›Removing the viscous damper and crankshaft add-on parts

Kohler KD27V12 — Removing the viscous damper and crankshaft add-on parts

Repair & overhaul

For the Kohler KD27V12, from the Kohler service manual.

Applies to: Kohler KD27V12, Kohler KD27V12 engine

Before you start

  • Damage to the crankshaft seal.
  • When removing the viscous damper make sure that the parts behind this do not move.

Procedure

  1. Remove the hexalobular screw and insert special tool [0528470].
  2. Remove the hexalobular screw and insert special tool [0528470].
  3. Remove the remaining hexalobular screws.
  4. Dismantle the pulley carefully without moving the parts behind it.
  5. Dismantle the viscous damper carefully without moving the parts behind it.

Tools required

  • Special tool [0528470] (two needed) Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Kohler KD27V12 →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →