Home›Repair guides›Kohler›Draining the coolant

Kohler KD27V12 — Draining the coolant

Maintenance · Cooling system

For the Kohler KD27V12, from the Kohler service manual.

Applies to: Kohler KD27V12, Kohler KD27V12 engine

Before you start

  • Hot cooler fluid! Injuries, burns!
  • Coolant can cause injuries to the eyes and allergic skin reactions!

Procedure

  1. Place a reservoir beneath the Diesel engine.
  2. Carefully loosen the sealing plug on the equalizing reservoir until the overpressure is released, then open it.
  3. Open the protecting cap of the drain valves.
  4. Screw drain hose [12690422 or 12690423] on the drain valves one after the other.
  5. When the coolant has drained, unscrew the drain hose from the drain valves.
  6. Screw the protecting caps back into place.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Let the engine cool down below 50°C (122°F) before opening the filler neck

Full service-parts list: Kohler KD27V12 →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.