Adjustments
For the Kohler KD 441, from the Kohler service manual.
Browse Kohler generators & specs →
Before you start
- Adjust the valve/rocker arm clearance when the engine is cold.
Procedure
- Adjust the valve/rocker arm clearance when the engine is cold.
- Turn the engine clockwise and place the piston at the TDC.
- Loosen lock nut A while locking lock nut B in its position.
- Set clearance at 0.10÷0.15 mm using a thickness gauge.
- Tighten lock nut A at a torque of 7 Nm.
Tools required
- Thickness gauge Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Clearance 0.10÷0.15 mm (engine cold)
- Lock nut A: 7 Nm
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.