For the Kohler KD 441, from the Kohler service manual.

Browse Kohler generators & specs →

Procedure

  1. After having adjusted the idling rate, operate lever A to accelerate the engine.
  2. Use screw 3 and regulate the top rate at 3800 rpm (for engines set at 3600 rpm on load).
  3. Fasten lock nut 4 keeping adjusting screw 3 in its position.

Specs & values

  • Top rate: 3800 rpm

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.