Home›Repair guides›Kohler›Injection pump delivery setting for engines with dynamometric brake

Kohler KD 441 — Injection pump delivery setting for engines with dynamometric brake

Adjustments

For the Kohler KD 441, from the Kohler service manual.

Browse Kohler generators & specs →

Procedure

  1. Start engine to idling speed.
  2. Unscrew delivery limiting device C.
  3. Accelerate the engine and load the dynamometric brake to obtain the power at the rpm required.
  4. Check that fuel consumption falls within the table specifications.
  5. Tighten limiting device C until the engine rpm slightly decreases and lock it with the lock nut.
  6. Completely release the brake and check the idle speed at which the engine settles.
  7. Set the idle speed with warm engine.
  8. Check valve clearance when engine has cooled down.
  9. Stop the engine.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Test conditions: R.P.M. 3600; Power 6.8 kW; Specific fuel consumption 273 g/kW.h; Time for 100 cc 162 sec

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.