Home›Repair guides›Kohler›Head tightening

Kohler KD 441 — Head tightening

Installation · Cylinder head

For the Kohler KD 441, from the Kohler service manual.

Browse Kohler generators & specs →

Procedure

  1. Lubricate the nuts and the washers with engine oil.
  2. 1st phase: tighten all 4 nuts M9 crossway to 5 Nm.
  3. 2nd phase: tighten all nuts in the same order to 20 Nm.
  4. 3rd phase: tighten all nuts in the same order to 30 Nm.
  5. 4th phase: tighten all nuts in the same order with further rotation of 90°.
  6. Tighten the 2 side nuts M6 to 10 Nm.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • M9 nuts: 5 Nm, 20 Nm, 30 Nm + 90°
  • M6 side nuts: 10 Nm

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →