Home›Repair guides›Kohler›Decompression lever, operation check

Kohler KD 441 — Decompression lever, operation check

Testing & diagnosis

For the Kohler KD 441, from the Kohler service manual.

Browse Kohler generators & specs →

Procedure

  1. Manually rotate the pulley clockwise up to the compression point.
  2. Operate the decompression lever by moving it up to position B.
  3. After bringing the engine at the T.D.C., check that the lever is in position B.
  4. The semiautomatic decompression lever should automatically return to resting position A by manually rotating the engine clockwise.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.