Kohler K361 — Valve Adjustment
Adjustments · Rocker arms / valves
For the Kohler K361, from the Kohler service manual.
Browse Kohler generators & specs →
Before you start
- Always use a new rocker arm housing gasket when housing is serviced.
Procedure
- Turn engine by hand until both valves are seated or in compression (TDC).
- Loosen the valve adjusting screw locknut.
- Screw adjusting screw in or out until clearance between end of rocker arm and valve stem is correct.
- Retighten locknut, then check clearance again.
- Rest rocker arm housing cover gasket on housing and fasten rocker arm cover to housing.
Tools required
- Feeler gauge Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Valve clearance .005 in. (0.13 mm) cold, both intake and exhaust
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.