Kohler K361 — Static Ignition Timing

Adjustments · Breaker points / flywheel timing marks

For the Kohler K361, from the Kohler service manual.

Browse Kohler generators & specs →

Procedure

  1. Disconnect spark plug lead from ignition coil; remove breaker point cover.
  2. Rotate engine by hand clockwise (viewed from flywheel end) until S mark is centered in timing sight hole.
  3. Points should just begin to break at the S mark; check with ohmmeter or continuity tester.
  4. Continue rotating engine until points reach maximum opening.
  5. Measure gap with feeler gauge; gap should be .020 in. fully open.
  6. Loosen point gap adjustment screw and readjust to .020 in. full open; tighten screw securely.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Breaker point gap .020 in. fully open
  • S mark = spark point 20 degrees before top dead center

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.