Kohler K361 — Choke Unit Replacement and Adjustment
Adjustments · Automatic choke (Thermo-Electric)
For the Kohler K361, from the Kohler service manual.
Browse Kohler generators & specs →
Before you start
- Always remove spark plug lead before working on or near carburetor or choke area.
Procedure
- Position the choke unit on the two mounting screws so that it is slightly loose.
- Hold the choke plate in the wide open position.
- Rotate choke unit clockwise (viewed from choke side) until it can no longer be rotated.
- Hold choke unit in position and tighten the two mounting screws.
- Check choke function by removing spark plug lead and cranking; choke valve should close a minimum of 45 degrees at about 75 degrees F.
Specs & values
- Choke valve closed 45 degrees minimum at about 75 degrees F
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.