Procedure
- Remove the rocker arm housing cover and spark plug.
- Turn engine over by hand until bottom dead center of intake stroke (intake valve closing).
- Mount a dial indicator on top of the exhaust clearance adjusting screw.
- Position exhaust rocker arm so adjusting screw contacts exhaust push rod; zero the dial indicator.
- Slowly turn flywheel clockwise and watch dial indicator; push rod lift should be .051-.059.
Tools required
- Dial indicator Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- ACR push rod lift .051-.059 in.
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.