Home›Repair guides›Kohler›Install Valve Cover

Kohler — Install Valve Cover

Installation · Cylinder Head

From a Kohler service manual covering: 1P14 690 11, XTX650, XTX675, XTX775. Check it applies to your exact model before use.

Browse Kohler generators & specs →

Before you start

  • Always use fresh sealant. Using outdated sealant can result in leakage.

Procedure

  1. Prepare sealing surfaces of cylinder head and valve cover; clean old RTV from surfaces.
  2. Apply a 1.5 mm (1/16 in.) bead of Permatex Ultra Grey sealant to valve cover as shown. Valve cover must be installed within 10 minutes of RTV application.
  3. Install valve cover and finger tighten screws.
  4. Using sequence shown, tighten cover screws to 8 N·m (71 in. lb.).

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Valve cover screw torque 8 N·m (71 in. lb.)
  • Sealant bead 1.5 mm (1/16 in.)

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →