Before you start
- Weep hole on backside of pump case must not be blocked; it prevents water entering engine if mechanical seal fails.
Procedure
- Apply Loctite 587 Ultra Blue or equivalent to screws.
- Replace pump case and hold in position.
- Secure with screws and washers.
- Torque pump case screws to 22.0 N·m (195 in. lb.).
Specs & values
- Pump case screws 22.0 N·m (195 in. lb.)
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.