Home›Repair guides›Kohler›Install Closure Plate

Kohler — Install Closure Plate

Installation · Crankcase

From a Kohler service manual covering: SH255, SH265, SH270. Check it applies to your exact model before use.

Applies to: Kohler SH255

Procedure

  1. Check that sealing surfaces of crankcase and closure plate are clean and free of nicks or burrs.
  2. Install dowel pins and a new closure plate gasket (dry) onto dowel pins.
  3. Install closure plate to crankcase; seat ends of camshaft into mating bearings. Rotate crankshaft slightly to engage governor gear teeth.
  4. Install screws securing closure plate. Torque screws in sequence shown to 24 N·m (212 in. lb.).

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Closure plate screws 24 N·m (212 in. lb.)

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.