Kohler SH255, SH265, SH270 — Spark Plug Inspection and Installation
For the Kohler SH255, SH265, SH270.
Applies to: Kohler Sh255
Procedure
- Clean out spark plug recess. Remove plug and replace.
- 1. Check gap using wire feeler gauge. Adjust gap, see specification table for adjustment.
- 2. Install plug into cylinder head.
- 3. Torque plug to 20 ft. lb. (27 Nm).
Tools required
- Wire feeler gauge
Specs & torque values
- Torque: 20 ft. lb. (27 Nm)
Source: manual:KOHLER_SH270_MANUALE_USO_MILTI_18_590_26_GLOBAL.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.