Procedure

  1. Clean out spark plug recess. Remove plug and replace.
  2. 1. Check gap using wire feeler gauge. Adjust gap, see specification table for adjustment.
  3. 2. Install plug into cylinder head.
  4. 3. Torque plug to 20 ft. lb. (27 Nm).

Tools required

  • Wire feeler gauge

Specs & torque values

  • Torque: 20 ft. lb. (27 Nm)

Source: manual:KOHLER_SH270_MANUALE_USO_MILTI_18_590_26_GLOBAL.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.