Kohler — Governed Idle Speed Adjustment
A Kohler service procedure — check it applies to your exact model before use.
Browse Kohler generators & specs →
Procedure
- Hold governor lever away from carburetor so throttle lever is against idle speed (RPM) adjustment screw of carburetor.
- Start engine and allow to warm up, then adjust screw to set approximately 1200 RPM. Check speed using a tachometer.
- Turn adjustment screw (inner) clockwise (in) to increase or counterclockwise (out) to decrease speed.
- Release governor lever and check that throttle lever is in idle position.
- Turn governed idle adjustment screw to obtain equipment manufacturer's recommended idle speed (1500-1800 RPM). Some engines have a bendable tab that is used to set this speed. A pliers should be used to bend this tab to achieve recommended speed.
- Move throttle lever to wide-open/full throttle position and hold in this position.
- Turn high speed screw to obtain intended high speed no-load RPM. Governed idle speed must be set before making this adjustment.
Tools required
- tachometer
- pliers
Specs & torque values
- 1500-1800 RPM
Source: manual:sm_24_690_06.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.