Home›Repair guides›Kohler›Governor Initial Adjustment - CH270

Kohler — Governor Initial Adjustment - CH270

Adjustments

From a Kohler service manual covering: CH270, CH395, CH440. Check it applies to your exact model before use.

Applies to: Kohler CH270, Kohler CH395, Kohler CH440

Procedure

  1. Close fuel shut-off valve.
  2. Remove air cleaner outer cover and access governor shaft and lever joint.
  3. Loosen governor lever mounting nut.
  4. Move governor lever clockwise until it stops.
  5. Rotate governor shaft clockwise until it stops.
  6. Hold both in position and tighten governor lever nut to 12 N·m (106 in. lb.).

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Governor lever nut torque 12 N·m (106 in. lb.)

Full service-parts list: Kohler CH270 →, Kohler CH395 →, Kohler CH440 →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.