Home›Repair guides›Kohler›Governor Initial Adjustment

Kohler — Governor Initial Adjustment

Adjustments · Governor System

From a Kohler service manual covering: SH255, SH265, SH270. Check it applies to your exact model before use.

Applies to: Kohler SH255

Procedure

  1. Close fuel shut-off valve.
  2. Remove air cleaner outer cover. Reposition fuel tank to access governor shaft and lever joint, or disconnect fuel line and remove tank.
  3. Loosen governor lever mounting nut.
  4. Move governor lever clockwise until it stops.
  5. Rotate governor shaft clockwise until it stops.
  6. Hold both in this position and torque governor lever nut to 10 N·m (88.5 in. lb.).

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Governor lever nut torque: 10 N·m (88.5 in. lb.)

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.