Home›Repair guides›Kohler›Install the security cover and bracket

Kohler GM22703-KP1 / GM22703-KP3 — Install the security cover and bracket

Installation · User interface security cover

For the Kohler GM22703-KP1 / GM22703-KP3, from the Kohler service manual.

Browse Kohler generators & specs →

Before you start

  • Foreign material contamination. Cover the transfer switch contactor and logic assembly during drilling to keep dirt, grit, metal drill chips, and other debris out of the components.

Procedure

  1. Drill six 5.6 mm (13/64 in.) diameter holes in the transfer switch door as shown. Remove burrs and metal chips.
  2. Attach the latch bracket (GM100212) to the outside surface of the door using three 10-32 nuts (X-6210-1). Do not final-tighten.
  3. Apply gasket material (25486 00350) to all four flanges on cover (GM89254), cutting strips to fit.
  4. Attach security cover (GM89254) to the outside surface of the door using three 10-32 nuts (X-6210-1). Do not final-tighten.
  5. Verify that the security door is level and that the security door and latch align. Adjust hardware and final-tighten the six nuts.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.