Home›Repair guides›Kohler›Install compression latch on security cover

Kohler GM22703-KP1 / GM22703-KP3 — Install compression latch on security cover

Installation · Security cover compression latch

For the Kohler GM22703-KP1 / GM22703-KP3, from the Kohler service manual.

Browse Kohler generators & specs →

Before you start

  • If the compression latch does not lock, verify that the security door is level. Verify that the security cover and latch bracket align. Adjust the hardware as necessary.

Procedure

  1. Remove the nut from the compression latch (GM51992).
  2. Place the padlock bracket (GM57166) and compression latch gasket on the compression latch (GM51992).
  3. Place the compression latch assembly in the hole of the security cover.
  4. Position the padlock bracket with the padlock holes horizontal. Install and tighten the mounting nut.
  5. Verify that the compression latch locks and unlocks the security cover. Adjust the hardware as necessary.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.