Home›Repair guides›Kohler›Fuel System Test

Kohler — Fuel System Test

Testing & diagnosis

From a Kohler service manual covering: SV710, SV715, SV720, SV725, SV730, SV735, SV740, SV810, SV820, SV830, SV840. Check it applies to your exact model before use.

Browse Kohler generators & specs →

Procedure

  1. Check for fuel in combustion chamber: disconnect and ground spark plug leads, close choke, crank engine several times, remove spark plug and check for fuel at tip.
  2. Check for fuel flow from tank to fuel pump: remove fuel line from inlet fitting of fuel pump, hold line below bottom of tank, open shut-off valve and observe flow.
  3. Check operation of fuel pump: remove fuel line from inlet fitting of carburetor, crank engine several times and observe flow.

Specs & values

  • Minimum fuel delivery rate must be 7.5 L/hr. (2 gal./hr.) with a pressure at 0.3 psi and a fuel lift of 24 in.
  • A 1.3 L/hr. (0.34 gal./hr.) fuel rate must be maintained at 5 Hz.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.