Home›Repair guides›Kohler›Fuel Shut-Off Solenoid Test

Kohler — Fuel Shut-Off Solenoid Test

Testing & diagnosis

From a Kohler service manual covering: CV17, CV18, CV20, CV22, CV23, CV25, CV26, CV730, CV740, CV745. Check it applies to your exact model before use.

Browse Kohler generators & specs →

Before you start

  • Gasoline is extremely flammable; keep sparks and open flames away.

Procedure

  1. Shut off fuel and remove solenoid from carburetor; have container ready to catch fuel.
  2. Wipe solenoid tip with shop towel or blow off with compressed air in a well ventilated area.
  3. Be sure power source is switched off; connect positive lead to red lead of solenoid, negative lead to solenoid body.
  4. Turn power source on and observe pin; pin should retract with power on and return when off.
  5. Test several times to verify operation.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →