Home›Repair guides›Kohler›Fuel Shut-Off Cup Cleaning

Kohler — Fuel Shut-Off Cup Cleaning

Maintenance · Fuel System

From a Kohler service manual covering: SH255, SH265, SH270. Check it applies to your exact model before use.

Applies to: Kohler SH255

Before you start

  • Explosive Fuel can cause fires and severe burns. Do not fill fuel tank while engine is hot or running.

Procedure

  1. Stop engine. Turn fuel shut-off lever to OFF position.
  2. Remove fuel shut-off cup. Clean fuel shut-off cup with solvent and wipe dry.
  3. Inspect for worn or damaged O-ring; replace as necessary.
  4. Place O-ring on fuel shut-off cup. Install cup and O-ring; rotate until finger tight. Turn with wrench 1/2 to 3/4 full turn.
  5. Turn fuel shut-off lever to ON position and check for leaks. If leaks, repeat steps 5 and 6.
  6. Tighten fuel tank cap securely.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Turn cup 1/2 to 3/4 full turn after finger tight

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.