Procedure
- Remove the thermostat and immerse it in boiling water
- Replace the thermostat if it does not open at least 0.230 after one minute at 212°F
- If the problem is insufficient heat, check the thermostat for leakage by holding it up to a lighted background
- Leakage of light all around the thermostat valve indicates the thermostat is unacceptable and should be replaced
Specs & values
- Thermostat must open at least 0.230 after one minute at 212°F
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.