For the Kohler Ford LSG-423, from the Kohler service manual.

Browse Kohler generators & specs →

Procedure

  1. Remove the thermostat and immerse it in boiling water
  2. Replace the thermostat if it does not open at least 0.230 after one minute at 212°F
  3. If the problem is insufficient heat, check the thermostat for leakage by holding it up to a lighted background
  4. Leakage of light all around the thermostat valve indicates the thermostat is unacceptable and should be replaced

Specs & values

  • Thermostat must open at least 0.230 after one minute at 212°F

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.