Kohler Ford LSG-423 — Starter Drive and Starter Test

Testing & diagnosis · Starting System

For the Kohler Ford LSG-423, from the Kohler service manual.

Browse Kohler generators & specs →

Before you start

  • The starter should not be operated continuously for periods longer than one minute at a time

Procedure

  1. Flood the warm engine by pumping the accelerator eight to ten times
  2. Turn the ignition key to start and hold it in the start position; the engine should fire immediately but should not start and run
  3. The starter should continue to crank the engine; this indicates a normal acceptable starter drive
  4. If the engine stops turning and the starter spins at high speed, the drive is not operating properly and should be replaced

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.