Home›Repair guides›Kohler›Fuel Pump Capacity (Volume) Test

Kohler Ford LSG-423 — Fuel Pump Capacity (Volume) Test

Testing & diagnosis · Fuel System

For the Kohler Ford LSG-423, from the Kohler service manual.

Browse Kohler generators & specs →

Procedure

  1. Operate the engine at the specified idle rpm
  2. Open the hose restrictor and expel fuel into the container while observing the time required to expel one pint
  3. Close the restrictor
  4. If the pump volume is below specifications, repeat the test using an auxiliary fuel supply and a new fuel filter
  5. If volume meets specifications with the auxiliary supply, check for a restriction in the fuel supply from the tank and for the tank not venting properly

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Minimum volume flow 1 Pint in 25 Seconds

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →