Home›Repair guides›Kohler›Crankcase Ventilation Regulator Valve Test

Kohler Ford LSG-423 — Crankcase Ventilation Regulator Valve Test

Testing & diagnosis · Positive Closed-Type Crankcase Ventilation System

For the Kohler Ford LSG-423, from the Kohler service manual.

Browse Kohler generators & specs →

Before you start

  • Do not disconnect the crankcase ventilation system and compensate with carburetor adjustments

Procedure

  1. With engine idling: remove PCV valve from its mounting but leave vacuum inlet side connected to hose; a hissing noise should be heard
  2. Check for a strong vacuum at the valve inlet and for vacuum leaks in the hose line and connections
  3. Reinstall PCV valve, then remove crankcase air inlet hose at air cleaner connection
  4. Loosely hold a small piece of stiff paper over the opening at the end of the inlet hose; after about a minute the paper should be sucked against the hose opening with noticeable force
  5. With engine stopped: remove PCV valve and shake it; a metallic clicking noise should be heard

Tools required

  • Crankcase Ventilation Tester C8AZ-6B627-A (alternate air intake test) Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.