Home›Repair guides›Kohler›Filling Cooling System

Kohler — Filling Cooling System

Maintenance

From a Kohler service manual covering: LH630, LH685, LH750, LH760. Check it applies to your exact model before use.

Browse Kohler generators & specs →

Before you start

  • Do not use antifreeze mixture greater than 70% ethylene glycol.
  • Do not use stop-leak additives.

Procedure

  1. Check condition of hoses, clamps, and components; replace as required.
  2. Mix 50% ethylene glycol with 50% distilled or deionized water.
  3. Fill cooling system through radiator neck; allow coolant to drain into lower areas.
  4. Fill overflow reservoir midway between ADD and FULL marks.
  5. Install radiator and reservoir caps.
  6. Start engine, run five minutes, then let cool.
  7. Check coolant level in reservoir and add if required.

Specs & values

  • Cooling system capacity approximately 2 L (2.18 qt.)

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.