Kohler — External Engine Inspection
A Kohler service procedure — check it applies to your exact model before use.
Browse Kohler generators & specs →
Procedure
- 1. Insert the stopper/hose into the oil fill hole. Leave
- 2. Start the engine and run at no-load high speed
- 3. Open the clamp and note the water level in the
- 4. Close the shut off clamp before stopping the
- 1. Remove the dipstick or oil fill plug/cap.
- 2. Install the adapter into the oil fill/dipstick tube
- 3. Push the barbed fitting on the gauge solidly into
- 4. Start the engine and bring it up to operating
- 5. Check the reading on the gauge. If the reading is
- 1. Disassemble breather, clean parts thoroughly,
- 2. Replace all worn or damaged seals and
- 3. Recondition piston, rings, cylinder bore, valves,
- 4. Repair/replace restricted muffler/exhaust
- 1. Crankcase breather clogged or inoperative.
- 2. Seals and/or gaskets leaking. Loose or
- 3. Piston blowby or leaky valves. (Confirm by
- 4. Restricted exhaust.
- 1. Run the engine for 3-5 minutes to warm it up.
- 2. Remove the spark plug(s) and the air filter from
- 3. Rotate the crankshaft until the piston (of cylinder
- 4. Install the adapter into the spark plug hole, but do
- 5. Connect an air source of at least 50 psi to the
- 6. Turn the regulator knob in the increase
- 7. Connect the tester quick-disconnect to the
- 8. Check the test results against the following table:
Source: manual:service-manual-cv17-745.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.