Procedure
- 1. Disconnect the kill lead from the ignition module
- terminal. See Figure 9-21.
- 2. Rotate flywheel magnet away from ignition mod-
- ule.
- 3. Remove the two hex flange screws and ignition
- module.
Source: manual:Kohler_Command_Series_Serv_Man.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.