Kohler — REMOVE MUFFLER
A Kohler service procedure — check it applies to your exact model before use.
Browse Kohler generators & specs →
Procedure
- 1. Remove the hex flange nuts from exhaust studs
- and hex flange screws from muffler bracket. See
- Figures 9-2 and 9-3.
- 2. Remove the muffler and gasket from exhaust out-
- let flange.
- 2. Remove the wing nut, washer, element cover,
- element and precleaner. See figure 9-5.
- 3. Remove the hex flange nuts from the intake studs,
- and the air cleaner base and gasket from the
- studs. See Figure 9-6.
- 4. Loosen the hose clamp and disconnect the
- breather hose from the rocker arm cover. Remove
- the air cleaner base from the studs and discon-
- nect choke linkage from the carburetor choke le-
- ver. See Figure 9-7.