HomeRepair guidesREMOVE BREATHER AND VALVE COVER

Kohler — REMOVE BREATHER AND VALVE COVER

A Kohler service procedure — check it applies to your exact model before use.

Browse Kohler generators & specs →

Procedure

  1. 1. Remove the hex. nut, copper washer, breather
  2. cover, and gasket. Refer to Figure 9-12.
  3. 3. Disconnect the leads from starter solenoid. Re-
  4. move the wire tie, self-tapping screws, solencid
  5. with bracket, and spacer. Refer to Figure 9-11,
  6. 2. Remove the filter, seal, breather plate, and gasket.
  7. Refer to Figure 9-13,

Source: manual:Magnum_M18_and_M20_Service_Manual.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.