Kohler — DISASSEMBLY
A Kohler service procedure — check it applies to your exact model before use.
Browse Kohler generators & specs →
Procedure
- 1. Remove the connector from rectifier-regulator.
- Remove the lead from center position of connec-
- tor. Remove the hex. cap screws and rectifier-
- regulator. Refer to Figure 9-9.
- 2. Remove the connector from key switch. Remove
- kill lead from connector. Remove the self-tapping
- screws and panel with key switch. Refer to
- Figure 9-10.
- 1. Remove the self-tapping screws and top baffle.
- 2. Remove the self-tapping screws and #1 side cyl-
- inder head baffle.
- 3. Remove the self-tapping screws and #2 side cyl-
- inder head baffle.
- 4. Remove the self-tapping screws and blower
- housing.
Specs & torque values
- 1
- 2
Source: manual:Magnum_M18_and_M20_Service_Manual.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.