Kohler — Figure 9-41. Removing Connecting Rod. 1. Remove the woodruff key from the flywheel taper
A Kohler service procedure — check it applies to your exact model before use.
Browse Kohler generators & specs →
Procedure
- 2. Remove the crankshaft from the crankcase. See
- REMOVE PISTON FROM CONNECTING Figure 9-44.
- ROD
- 1. Remove the wrist pin retainer and wrist pin. Sepa-
- rate the piston from the connecting rod. See Fig-
- ure 9-42.
- Crankshaft
- Piston
- Wrist Pin
- Retainer
- Connecting
- Rod
- Figure 9-44. Removing Crankshaft.
- | REMOVE FLYWHEEL END OIL SEAL
- Figure 9-42. Removing Piston From Connecting AND BEARING
- Rod. 1. Remove the oil seal from crankcase.
- 2. Remove the bearing from the crankcase using
- 1. Remove the top and center compression rings handle #NU-4747 and bearing remover
- using a ring expander tool. See Figure 9-43. #KO-1029. See Figure 9-45.
- 1. Remove the hitch pin and plain washer from gov-
- ernor cross shaft. See Figure 9-46.
- 2. Remove the cross shaft and plain washer from the
- crankcase.
- Figure 9-47. Removing Cross Shaft Oil Seal.
Tools required
- 1. Remove the top and center compression rings handle #NU-4747 and bearing remover
- using a ring expander tool. See Figure 9-43. #KO-1029. See Figure 9-45.
Specs & torque values
- KO-1029
- NU-4747
Source: manual:Kohler_Command_Series_Serv_Man.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.