Kohler — GENERATOR DISASSEMBLY — REASSEMBLY
For these Kohler models: 10/15RMOY, 15/17.5ROY, 15RMY, 22.5-47.5ROZ, 22.5/32.5RZ.
Applies to: Kohler 15Rmy, Kohler 22 5 47 5Roz
Procedure
- 6. Place wood block(s) under flywheel housing to sup-
- port engine; lower, allowing flywheel housing to
- lightly rest on wood blocks (Figure 4-21).
- Figure 4-21. Hoisting Generator
- 7. Remove generator fan guard (Figure 4-22).
- 10.
- 11.
- 12.
- 13.
- 1. Fan Guard
- Figure 4-22. Fan Guard
- Remove bolts mounting generator adapter to
- flywheel housing (Figure 4-23),
- Remove nuts holding fan and drive discs to flywheel
- (Figure 4-24).
- Guide generator fan off of studs and remove spacers.
- If studs hold drive discs to flywheel, work drive discs
- over studs to separate generator from engine (Figure
- 4-25).
- Loosen four stator-to-end bracket and four stator-to-
- adapter attachment bolts to where they can be turned
- by hand (47.5kW). Loosen four overbolts to where
- they can be turned by hand (all other models) (Fig-
- ures 4-26 and 4-27).
- Carefully hoist generator assembly (end bracket
Tools required
- Figure 4-23. Adapter Mounting Bolts
- 1. Generator Adapter 4. Drive Discs
- adapter attachment bolts to where they can be turned
Source: manual:R Series Service TP5074.PDF. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.