Kohler — Service Procedure
For these Kohler models: CH5, CH6.
Applies to: Kohler Ch5, Kohler Ch6
Before you start
- NOTE: Choke control must be in the “OFF”
- NOTE: Be sure retainer is hooked on tabs.
Procedure
- 5. When servicing the air cleaner, check the air
- Cleaner base. Make sure it is secured and not
- bent or damaged. Also check the air cleaner ele-
- ment retainer for damage or improper fit. Replace
- all bent or damaged air cleaner components.
- 6. Reinstall the paper element, element retainer, and
- precleaner as follows:
- a. Place the paper element into the air cleaner
- base.
- NOTE: The pleats must run parallel to the
- cylinder.
- b. Hook the element retainer into the top of the air
- cleaner base. Then hook the retainer into the
- bottom of the base to hold the paper element in
- place.
- NOTE: Be sure retainer is hooked on tabs.
- c. Tighten the four slot head screws evenly.
- NOTE: These screws must be snug to
- eliminate any air leaks around paper
- element.
Source: manual:6hpKohlerServiceManual.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.