Kohler — Service Procedure
A Kohler service procedure — check it applies to your exact model before use.
Browse Kohler generators & specs →
Before you start
- NOTE: The governor gear is held onto the gover-
Procedure
- 3. Remove the governor cross shaft oil seal from the
- crankcase. See Figure 9~47.
- Figure 9-48. Removing Governor Gear.
- NOTE: The governor gear is held onto the gover-
- nor gear shaft by small molded tabs in the
- gear. When the gear is removed from the
- shaft these tabs are destroyed. This will
- require replacement of the gear; therefore,
- remove the gear only if absolutely neces-
- sary (such as when reboring, doing major
- engine rebuilding, etc.).
- 9.12
- 1. Manual (retractable) starting is much easier. With-
- out ACR, manual starting would be virtually impos-
- sible.
- 2. Electric start models can use a starter and battery
- size that are practical for the applications in which
- these engines are used.
- 3. ACR eliminates the need for a spark retard/ad-
- vance mechanism. A spark retard/advance
Source: manual:Kohler_Command_Series_Serv_Man.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.