Kohler — the kill lead to the crankcase. Remove the four
A Kohler service procedure — check it applies to your exact model before use.
Browse Kohler generators & specs →
Before you start
- NOTE: The intake hydraulic lifter is farthest from
- NOTE: Insert the screwdriver only in the splitting
Procedure
- 2. Locate the splitting notches in the seam of the
- closure plate and crankcase. See Figure 9~34. Pry
- the closure plate from the crankcase using a large
- flat-blade screwdriver.
- Kill Leada
- e
- :
- .
- *
- Hex Flange Screw & Clip’
- i
- Figure 9-32. Removing Stator.
- 1. Remove the twelve hex flange screws securing
- the closure plate to the crankcase. S
- ee Figure
- 9-33.
- Closure Plate
- Figure 9-33. Removing Closure Plate.
- Figure 9-34. Splitting Notch of Closure Plate/
- Crankcase.
Tools required
- 3. Remove the hex socket screw, oil pressure relief
Source: manual:Kohler_Command_Series_Serv_Man.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.