Before you start
- NOTE: The valve cover is sealed to the cylinder head
Procedure
- 1. Remove the five hex flange valve cover screws
- and valve cover from the cylinder head assembly.
- See Figure 9-18.
- NOTE: The valve cover is sealed to the cylinder head
- using RTV silcone sealant. When removing
- valve cover, use care not to damage the gas-
- ket surfaces of cover and cylinder head.
- Figure 9-18. Removing Valve Cover.
- 1. Remove the hex flange screws securing the cylin-
- der head baffle to the cylinder head. See Figure
- 9-19. Remove the baffle.
- Figure 9-19. Removing Cylinder Head Baffle.
- 1. Remove the hex flange screws from blower hous-
- ing and baffles. Disconnect wire hamess from the
- key switch, if equipped. Remove the blower hous-
- ing and baffles.
- Figure 9-20. Removing Blower Housing and
- Baffles.
- 1. Disconnect the kill lead from the ignition module
- terminal. See Figure 9-21.