Home›Repair guides›Kohler›Emergency Stopping (Dee-3 Controller)

Kohler — Emergency Stopping (Dee-3 Controller)

Operation

From a Kohler service manual — check it applies to your exact model before use.

Browse Kohler generators & specs →

Procedure

  1. Turn Generator Master Switch to the OFF/RESET position or operate remote Emergency Stop switch for immediate shutdown.
  2. If Emergency Stop switch is activated, the controller Emergency Stop lamp will light and the unit will shut down.
  3. When Emergency Stop Switch is reset by replacing glass face, the Auxiliary lamp will light.
  4. Move Generator Master Switch to OFF/RESET position to reset generator and resume operation.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.