Home›Repair guides›Kohler›EBSM Connection and Voltage Setting

Kohler — EBSM Connection and Voltage Setting

Installation · External Battery Supply Module (EBSM)

From a Kohler service manual — check it applies to your exact model before use.

Browse Kohler generators & specs →

Before you start

  • If the battery connections are reversed, red LED1 or LED2 will light.

Procedure

  1. Use #14-28 AWG wire to connect one or two batteries to terminal block TB13. A second battery can be connected but is not required.
  2. Follow the marking on the board for the positive (+) and negative (-) connections.
  3. Set voltage selector switch SW11-1 to 12 or 24 VDC. Switch SW11-2 is not used.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • DIP switch SW11-1 OFF = 12 VDC; ON = 24 VDC.
  • The EBSM must be the last board on the bus and has no address switches.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.