Home›Repair guides›Kohler›Draining Cooling System

Kohler — Draining Cooling System

Maintenance

From a Kohler service manual covering: AEGIS 17, AEGIS 20, AEGIS 23, LV560, LV625, LV675. Check it applies to your exact model before use.

Browse Kohler generators & specs →

Before you start

  • Do not remove plugs when engine is hot.

Procedure

  1. Stop engine and let cool sufficiently.
  2. Remove upper blower housing and screen assembly.
  3. When cool, slowly remove radiator cap.
  4. Remove coolant drain plug in lower side of both cylinder heads; drain coolant.
  5. Apply pipe sealant with Teflon to threads; reinstall plugs; torque to 13.5 N·m (120 in. lb.).
  6. Loosen two screws holding overflow reservoir retainer bracket.
  7. Remove reservoir cap, lift bracket, remove reservoir; drain and clean.
  8. Reinstall reservoir; torque bracket screws to 7.3 N·m (65 in. lb.); reinstall cap.
  9. Flush cooling system.

Specs & values

  • Use brass (soft) plugs Kohler Part No. 66 139 01-S on service.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.