Home›Repair guides›Kohler›DLA Clevis Shaft Reinstall

Kohler — DLA Clevis Shaft Reinstall

Adjustments · Electronic governor

From a Kohler service manual covering: ECV850, ECV860, ECV870, ECV880. Check it applies to your exact model before use.

Browse Kohler generators & specs →

Before you start

  • Do not force clevis shaft; damage can occur.

Procedure

  1. Disconnect linkage and remove DLA from bracket.
  2. Remove clevis shaft completely from DLA.
  3. Reinstall rubber boot if required.
  4. Insert clevis shaft into actuator; rotate clockwise 3 full turns.
  5. Confirm keyway aligned with key; press shaft into actuator.
  6. Reinstall DLA; torque screws to 4.1 N·m (35 in. lb.).

Specs & values

  • DLA mounting screw torque: 4.1 N·m (35 in. lb.)

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.