Kohler — Contact Set Removal (145-400 Ampere Contactors)
Repair & overhaul
From a Kohler service manual — check it applies to your exact model before use.
Browse Kohler generators & specs →
Procedure
- Loosen captive quarter-turn fasteners and remove contactor cover.
- If contactor is rated at 400 amperes, pull pole outward, locate and remove retaining pin, and then remove and discard pole.
- If contactor is not rated at 400 amperes, push and hold lower portion of pole inward; press top of pole downward into retaining clip; rotate lower portion outward and remove and discard pole.
- Using L-wrench, loosen screw and remove and discard upper contact.
- Repeating step 4, remove and discard lower contact.
- Repeating steps 2 through 5, remove and discard remaining poles and contacts.
Tools required
- L-wrench Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.