Home›Repair guides›Kohler›Connecting Engine Start and Optional Load Control Circuits

Kohler — Connecting Engine Start and Optional Load Control Circuits

Installation · MPAC 550 controller connectors P1 and P3

From a Kohler service manual — check it applies to your exact model before use.

Browse Kohler generators & specs →

Procedure

  1. Connect the generator set engine start leads to 2-pin connector P1 on the controller.
  2. Optional: connect the load control circuit to 2-pin connector P3 on the controller.
  3. Tighten the Engine Start connections to 0.8 Nm (7 in. lb.).
  4. Tighten the Load Control connections to 0.8 Nm (7 in. lb.).

Specs & values

  • Engine Start: 0.5 A @ 125 VAC; 2 A @ 30 VDC, SPST normally closed
  • Load Control: 10 A @ 120 VAC, SPST normally open
  • 0.8 Nm (7 in. lb.)

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.