Home›Repair guides›Kohler›Coil Installation (25-80 Ampere Contactors)

Kohler — Coil Installation (25-80 Ampere Contactors)

Repair & overhaul

From a Kohler service manual — check it applies to your exact model before use.

Browse Kohler generators & specs →

Procedure

  1. Install the coil in the contactor base.
  2. Reconnect wire harness leads to coil and tighten screws.
  3. Install contact assembly on contactor base and tighten screws.
  4. Reconnect wire harness leads to auxiliary switch.
  5. Reconnect leads between load terminals of the two contactors.
  6. Reconnect load and power source leads to contactor terminals.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.